By: RTI | Version: 1.2 | Updated: June 5, 2026
Driver for Allen & Heath AHM series products. Supports up to 64×64 configurations with room combining.
Configuration
IP Address: Assigned IP of the device.
Input Count: Number of inputs to use.
Control Group Count: Number of control groups.
Update Interval: 1–60 seconds polling interval.
Set Level commands use a 0–123 scale. Use formula: [(Gain(dB)+48)/58]*127 for specific dB values.
Room Combining
Room combine/divide accepts room numbers 1–10. When dividing rooms, always use the lower room number as the first parameter.
Version History
1.0 — Initial release.
1.01 — Fixed zone filtering on input commands.
1.1 — Adds room combine feature.
1.2 — Fixed crash on initialization; fixed queue deadlock; fixed Group channel names loading; improved reconnection logic.
Support
Email: [email protected]